Medical equipment for sterilization

9 products

Sterilization and storage - safe reprocessing of endoscopes and instruments

The sterilization and storage system provides a complete reprocessing cycle: pretreatment, automated washing and disinfection, drying, and controlled storage. The MediGo section offers washable disinfectors, drying cabinets and loading accessories, as well as specialized products such as flexible endoscope storage cabinets and sterilization boxes for instruments. This helps to maintain infection control and traceability in endoscopy rooms and CDCs.
See the range and subcategories below.

Where are sterilization and storage solutions used?

  • Endoscopy departments. Washing, high-level disinfection, drying and safe storage of flexible endoscopes between procedures.
  • Centralized processing/sterilization departments. Centralized processing of endoscopic and general surgical instruments with clear routing "dirty → clean → sterile area".
  • Operating rooms and day surgery. Quick return of instruments to work thanks to automated cycles and drying.
  • Private clinics and diagnostic centers. Cost optimization through rational loading, water/chemical savings, and reduced manual operations.

Main subcategories

  • Washing disinfectors - automatic cleaning and disinfection of instruments and endoscopes with protocol-based programs.
  • Drying cabinets - channel drying and controlled blowing/filtration before storage.
  • Loading accessories - baskets, cassettes, holders, and adapters for proper placement and tracing.

Key features and capabilities

  • Automated cycles. Programmable steps (mechanical cleaning → thermal/chemical disinfection → rinsing) with minimized manual contact.
  • Productivity and resource savings. Optimized water/chemical consumption, water hardness control, automatic dosing; support for logs and endoscope/operator identification.
  • Drying and storage. Air-filtered channel drying (HEPA/ULPA depending on model) and safe storage modes to prevent recontamination.
  • Ergonomics and safety. Convenient baskets/cassettes, tight connections, leak detectors, end-of-cycle alarms, status indicators, and error lockout.
  • Compatible with infection control protocols. Compliance with reprocessing requirements for flexible endoscopes and general surgical instruments.

How to choose a sterilization and storage solution?

  • Flow and range of instruments. Estimate the number of procedures/shifts, types of endoscopes and accessories - this determines the workload and the number of chambers/posts.
  • Modes and logging. Do you need advanced protocols, Scope ID/operator ID, label printing, data export to the medical information system?
  • Water treatment and chemistry. Availability of filtration, hardness control and dosing; compliance with the equipment manufacturer.
  • Drying/storage. Blowing, filtration, cycle time and cabinet capacity; availability of a vertical suspension for flexible endoscopes.
  • Service and warranty. Installation, training, scheduled maintenance, availability of consumables and spare parts.

Why buy sterilization and storage equipment from MediGo?

We advise on the selection, help with installation and staff training. Delivery across Ukraine: pickup in Kyiv, MediGo courier in Kyiv for free from UAH 30,000 and Nova Poshta across the country; preparation/dispatch - up to 3 days, for "out of stock" items - up to 90 days. Returns - within 14 days, provided that the item is in good condition. The typical warranty is 12-36 months; post-warranty service is available. Details: delivery and payment, returns and exchanges, service.

FAQ

How is a washable disinfector different from a sterilizer?

A washable disinfector automates cleaning and disinfection (including thermal/chemical), while a sterilizer destroys all forms of microorganisms and spores at high temperatures or by other means. In the reprocessing of endoscopes, both stages complement each other.

Why do we need an endoscope drying cabinet?

It removes residual moisture from the channels under filtered airflow and provides a controlled storage environment that reduces the risk of recontamination before the next procedure.

What accessories are required for proper loading?

Baskets/cassettes, instrument holders, and channel adapters help to properly position endoscopes and accessories in the chamber, improving processing quality and traceability.

What are the delivery, return, and warranty terms at MediGo?

Pickup in Kyiv; MediGo courier - free of charge from UAH 30,000; within Ukraine - Nova Poshta. Preparation/dispatch - up to 3 days (out-of-stock items - up to 90 days). Returns - 14 days; warranty is usually 12-36 months; post-warranty service is available.

Quick Order
Everything worked out!
tnx
Thank you for your order. the manager will contact you to clarify the data.
Choose your city
Specify the settlement of Ukraine
    Moderation review
    Everything worked out!
    tnx
    Your comment is under moderation. Thank you for your opinion.
    Consultation required
    Fill out the form and we will contact you as soon as possible
    Check the price
    Fill out the form and we will contact you as soon as possible
    Your request is accepted
    Everything worked out!
    tnx
    Your request is under moderation. Thank you for your proposal.
    Your request is accepted
    Everything worked out!
    tnx
    Your request is under moderation. Thank you for your proposal.